How to Calculate Battery Runtime
Direct answer
Runtime (hours) = usable kWh ÷ load (kW). For a 5.12kWh LiFePO4 pack: usable = 5.12 × 0.90 DoD = 4.6 kWh, minus 10% inverter loss ≈ 4.1 kWh delivered. At a 1kW load that is 4 hours; at 2kW, 2 hours. Match this to your outage length.
The formula
usable_kWh = rated_kWh × DoD delivered_kWh = usable_kWh × inverter_efficiency runtime_h = delivered_kWh ÷ load_kW
Worked example
| Load | 1× 5.12kWh | 2× (10.24kWh) |
|---|---|---|
| 500W | 8 hr | 16 hr |
| 1kW | 4 hr | 8 hr |
| 2kW | 2 hr | 4 hr |
LiFePO4 uses 90% DoD vs lead-acid's 50%, which is why it delivers nearly double the runtime for the same labeled kWh. See the LiFePO4 vs lead-acid guide and the price guide for 48V 100Ah packs ($620-780 FOB).
Frequently asked questions
How long will a 5kWh battery run a 1kW load?
About 4.5 hours. Use: runtime = usable kWh ÷ load kW. A 5.12kWh LiFePO4 pack has 4.6 kWh usable at 90% DoD, minus 10% inverter loss. So 4.6 ÷ 1.0 × 0.9 ≈ 4.1 hours; most inverters are 90-95% efficient, giving 4-4.5 hours for a 1kW load.